PRODUCTS | FIRE RESISTANT CABLES

LIHH-TP FE180 PH120

LIHH-TP FE180 PH120

Quality Certificates

You can click on the logos to see the Quality Certificates.

Application

These cables are used in industrial electronics, control engineering applications, electronic devices and automation systems, fire alarm and supression systems especially in public buildings such as hotels, schools, hospitals, shopping centers etc. They have low smoke density and they don’t emit poisonous and corrosive gases during a fire therefore they don’t harm human health. They can function under flame for 180 minutes according to tests done as per IEC 60331-21 and maintain 120 minutes circuit integrity according to tests done as per EN50200 which simulate the fire and hazardous conditions.

Construction
Conductor IEC 60228, EN 60228, VDE 0295 CLASS-5 Stranded electrolytic annealed copper wire
Insulation Cross-linked elastomer silicone insulation | BS EN 50363-1, HD 22.1 S4(EI2)
Colour Code DIN 47100                      
Lay up Two cores twisted in pair and pairs stranded together
Separator Polyester tape
Flame Barrier Fiberglass tape
Outher sheath HFFR | EN 50290-2-27, VDE0207(HM2)
Outher Sheath Colour RAL 2004 Orange
Specifications
Conductor Resistance
Cross section (mm2) Ω/km (max.)
0,75 26
1,0 19,5
1,5 13,3
2,5 7,98
Insulation Resistance >200MΩ.km
Operating Voltage 300/500 V
Test Voltage 1000 V
Temperature Range -30°C   –   +90°C (fixed)
Min. Bending Radius 7,5 x  cable diameter
Flame tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1 
Smoke Density IEC 61034-2, EN 61034-2
Corressive Gas Tests IEC 60754-1, EN 50267-2
Circuit Integrity Tests                FE180 IEC 60331-21
Circuit Integrity Tests  PH120 EN 50200
         
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401120802 2x2x0,75 8,4 26,5 69
3401120803 3x2x0,75 9,5 41 98
3401120804 4x2x0,75 10,9 54 135
3401120805 5x2x0,75 11,8 68 162
3401120806 6x2x0,75 12,3 80 182
3401120808 8x2x0,75 13,4 104 220
3401120810 10x2x0,75 15,8 131 285
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401121002 2x2x1,00 8,8 36 88
3401121003 3x2x1,00 10,2 53 124
3401121004 4x2x1,00 11,7 71 160
3401121005 5x2x1,00 12,4 90 192
3401121006 6x2x1,00 12,9 107 240
3401121008 8x2x1,00 14 143 305
3401121010 10x2x1,00 15,7 181 370
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401121502 2x2x1,50 11 52 128
3401121503 3x2x1,50 11,9 77 174
3401121504 4x2x1,50 13,8 103 224
3401121505 5x2x1,50 15,4 130 270
3401121506 6x2x1,50 16,2 154 330
3401121508 8x2x1,50 17,1 206 422
3401121510 10x2x1,50 19,4 260 540
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401122502 2x2x2,50 12,5 85 185
3401122503 3x2x2,50 14 128 252
3401122504 4x2x2,50 16,2 171 330
3401122505 5x2x2,50 17,5 214 410
3401122506 6x2x2,50 18,8 257 505
3401122508 8x2x2,50 20 343 655
3401122510 10x2x2,50 21,8 430 805