PRODUCTS | FIRE RESISTANT CABLES

LIHCH FE180 PH120

LIHCH FE180 PH120

Quality Certificates

You can click on the logos to see the Quality Certificates.

Application

These cables are used in industrial electronics, control engineering applications, electronic devices and automation systems, fire alarm and supression systems especially in public buildings such as hotels, schools, hospitals, shopping centers etc. They have low smoke density and they don’t emit poisonous and corrosive gases during a fire therefore they don’t harm human health. They can function under flame for 180 minutes according to tests done as per IEC 60331-21 and maintain 120 minutes circuit integrity according to tests done as per EN50200 which simulate the fire and hazardous conditions.

Construction
Conductor IEC 60228, EN 60228, VDE 0295 CLASS-5 Stranded electrolytic annealed copper wire
Insulation Cross-linked elastomer silicone insulation | BS EN 50363-1, HD 22.1 S4(EI2)
Colour Code DIN 47100                      
Lay up Cores stranded in layers
Separator Polyester tape
Flame Barrier Fiberglass tape
Screen Tinned copper wire braiding
Outher sheath HFFR | EN 50290-2-27, VDE0207(HM2)
Outher Sheath Colour RAL 2004 Orange
Specifications
Conductor Resistance
Cross section (mm2) Ω/km (max.)
0,75 26
1,0 19,5
1,5 13,3
2,5 7,98
Insulation Resistance >200MΩ.km
Operating Voltage 300/500 V
Test Voltage 1000 V
Temperature Range -30°C   –   +90°C (fixed)
Min. Bending Radius 7,5 x  cable diameter
Flame tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1 
Smoke Density IEC 61034-2, EN 61034-2
Corressive Gas Tests IEC 60754-1, EN 50267-2
Circuit Integrity Tests                FE180 IEC 60331-21
Circuit Integrity Tests  PH120 EN 50200
         
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401200802 2x0,75 6,1 25 53
3401200803 3x0,75 6,8 34 65
3401200804 4x0,75 8,2 41 80
3401200805 5x0,75 8,4 51 96
3401200806 6x0,75 8,9 60 115
3401200808 8x0,75 9,4 78 128
3401200810 10x0,75 12,1 95 170
3401200820 20x0,75 15,2 170 305
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401201002 2x1,00 6,4 32 68
3401201003 3x1,00 6,7 40 83
3401201004 4x1,00 7,8 53 100
3401201005 5x1,00 8,5 64 122
3401201006 6x1,00 9,2 74 145
3401201008 8x1,00 10,4 100 185
3401201010 10x1,00 12,3 120 212
3401201020 20x1,00 15,8 230 400
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401201502 2x1,50 7,7 44 85
3401201503 3x1,50 8,2 58 105
3401201504 4x1,50 9 74 135
3401201505 5x1,50 10,6 92 160
3401201506 6x1,50 11 110 190
3401201508 8x1,50 12,2 136 240
3401201510 10x1,50 14,4 174 294
3401201520 20x1,50 18,3 314 520
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401202502 2x2,50 9 63 118
3401202503 3x2,50 9,5 88 150
3401202504 4x2,50 11 115 200
3401202505 5x2,50 12,2 140 235
3401202506 6x2,50 12,8 170 280
3401202508 8x2,50 14,2 215 350
3401202510 10x2,50 16,3 270 440
3401202520 20x2,50 21 498 790