PRODUCTS | INSTRUMENTATION CABLES

 

RE-2X(St)Y-fl-PiMF

RE-2X(St)Y-fl-PiMF

Application
Instrumentation cables are preferred in the industrial applications of petrochemical plants, power plants, steel & aluminium factories, water treatment plants, pipelines and industrial buildings of the oil and gas industry and similar projects where measurement and control of data is crucial and the project environment can be demanding. Birikim Kablo follows national/international standards or customers specific requests when designing these cables.
Construction
Reference Standard EN 50288-7
Conductor IEC 60228, CLASS-2 Stranded electrolytic annealed copper wire
Insulation XLPE | EN 50290-2-29
Colour Code Pair : White-black cores  with numbers      
Triple : White-black-red cores  with numbers                                         
Drain wire Tinned solid copper wire
Individual screen Polyester tape, Aluminium foil 100% coverage
Lay up Two cores twisted in pair and pairs stranded together
Screen Polyester tape, Aluminium foil 100% coverage
Drain wire Stranded Tinned Copper
Outer sheath Flame Retardant, UV Resistant PVC  | EN 50290-2-22 
Outer Sheath Colour RAL 5015 Blue , RAL 9005 Black
Specifications
Mutual Capacitance (800 MHz)  150(pF/m)
Capacitance Unbalance 500 pF/ 500 m
Insulation Resistance >5000MΩ.km
Conductor Resistance
Cross Section  (mm2) Conductor resistance Ω/km (max.) L/R Ratio(µH/Ω)
0,5 36 25
0,75 24,5 25
1 18,1 25
1,3 14,2 40
1,5 12,1 40
2,5 7,41 60
Operating Voltage 300/500 V
Test Voltage 2000 V
Temperature Range -30°C   –   +90°C (fixed)
Min. Bending Radius 7,5 x  cable diameter
Oil Resistance ICEA S-82-552
Flame tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1
IEC 60332-3-24 , EN 60332-3-24 
Alternative designs: Yw – Heat resistant PVC (105 °C)
TiMF and QiMF screen types
C – Copper or tinned copper braided
Yv/Hv – Reinforced outer sheath
RE-2G - Fire resistant (silicon based)
RE-m2X - Fire resistant (mica tape based)
Communication core can be added upon request
   
Product Code  Number of  Cores × Cross section (mm2) Cable Diameter (mm ±5%) Copper Weight  (kg/km) Cable Weight  (kg/km)
33102110504 2x2x0,50 8,3 35 87
33102110508 4x2x0,50 10,1 59 130
33102110516 8x2x0,50 13 107 228
33102110520 10x2x0,50 14,7 132 280
33102110524 12x2x0,50 15,65 156 325
33102110532 16x2x0,50 17,6 204 422
33102110540 20x2x0,50 19,2 254 510
33102110548 24x2x0,50 21,5 304 615
         
33102110804 2x2x0,75 9,1 46 105
33102110808 4x2x0,75 11 80 170
33102110816 8x2x0,75 14,2 150 294
33102110820 10x2x0,75 16,5 182 363
33102110824 12x2x0,75 18,1 216 435
33102110832 16x2x0,75 19,6 284 542
33102110840 20x2x0,75 21,2 352 658
33102110848 24x2x0,75 23,8 420 782
         
33102111004 2x2x1,0 9,6 56 120
33102111008 4x2x1,0 11,9 100 198
33102111016 8x2x1,0 15,2 188 346
33102111020 10x2x1,0 17,6 232 428
33102111024 12x2x1,0 18,8 275 505
33102111032 16x2x1,0 21,2 363 655
33102111040 20x2x1,0 24,9 450 810
33102111048 24x2x1,0 26,7 536 960
         
33102111304 2x2x1,3 11,1 70 154
33102111308 4x2x1,3 13,8 136 248
33102111316 8x2x1,3 17,4 262 455
33102111320 10x2x1,3 20,1 320 565
33102111324 12x2x1,3 21,2 378 662
33102111332 16x2x1,3 24 498 855
33102111340 20x2x1,3 27,1 620 1040
33102111348 24x2x1,3 29,6 742 1260
         
33102111504 2x2x1,5 11,3 80 160
33102111508 4x2x1,5 14 140 262
33102111516 8x2x1,5 18,2 266 472
33102111520 10x2x1,5 20,8 322 582
33102111524 12x2x1,5 22 390 685
33102111532 16x2x1,5 24,6 516 880
33102111540 20x2x1,5 27,1 638 1090
33102111548 24x2x1,5 30,8 764 1305
         
33102112504 2x2x2,5 13,3 132 238
33102112508 4x2x2,5 15,9 236 390
33102112516 8x2x2,5 20,65 440 700
33102112520 10x2x2,5 24,2 542 870
33102112524 12x2x2,5 25,75 640 1035
33102112532 16x2x2,5 28,3 845 1330
33102112540 20x2x2,5 30,45 1.046 1680
33102112548 24x2x2,5 36,3 1.250 1985