PRODUCTS | DATA CABLES

LI02Y(St)CH-TP PiMF RS 485

LI02Y(St)CH-TP PiMF RS 485

Application
They are used in data and information communication in electronic control systems.
Construction
Conductor Stranded tinned electrolytic annealed copper wire
Insulation FOAM SKIN PE | EN 50290-2-23  
Colour Code Black/red – black/White – black/green – black/blue                                                                           
Lay up Two cores twisted in pair
Separator Polyester tape    
Individual screen Aluminium foil 100% coverage, Tinned copper drain wire
Lay up Two cores twisted in pair and pairs stranded together
Separator Polyester tape    
Foil Screen Aluminium foil 100% coverage, Tinned copper drain wire 
Screen Tinned copper wire braiding  
Outer sheath HFFR | EN 50290-2-27, VDE0207(HM2)
Outer Sheath Colour RAL 7001 Grey
Specifications
Cross Section(mm2)      Ω/km (max.) 
Loop resistance 0,22mm²                                    186
  0,34mm²                                    115        
  0,50mm²                                     78
Mutual Capacitance 46 pF/m
Impedance 120±15 Ω
Insulation Resistance >2000MΩ.km
Operating Voltage 250 V 
Test Voltage 1,2 kV 
   
Temperature Range -30°C   –   +70°C / (fixed)
Min. Bending Radius   10 x  cable diameter
Smoke Density IEC 61034-2, EN 61034-2
Corrosive Gas Tests IEC 60754-1, EN 50267-2
Flame Tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1