LIHCH-TP FE180 PH120

 

LIHCH-TP FE180 PH120

Application

These cables are used in industrial electronics, control engineering applications, electronic devices and automation systems, fire alarm and supression systems especially in public buildings such as hotels, schools, hospitals, shopping centers etc. They have low smoke density and they don’t emit poisonous and corrosive gases during a fire therefore they don’t harm human health. They can function under flame for 180 minutes according to tests done as per IEC 60331-21 and maintain 120 minutes circuit integrity according to tests done as per EN50200 which simulate the fire and hazardous conditions.

Construction
Conductor IEC 60228, EN 60228, VDE 0295 CLASS-5 Stranded electrolytic annealed copper wire
Insulation Cross-linked elastomer silicone insulation | BS EN 50363-1, HD 22.1 S4(EI2)
Colour Code DIN 47100                      
Lay up Two cores twisted in pair and pairs stranded together
Separator Polyester tape
Flame Barrier Fiberglass tape
Screen Tinned copper wire braiding
Outher sheath HFFR | EN 50290-2-27, VDE0207(HM2)
Outher Sheath Colour RAL 2004 Orange
Specifications
Conductor Resistance
Cross section (mm2) Ω/km (max.)
0,75 26
1,0 19,5
1,5 13,3
2,5 7,98
Insulation Resistance >200MΩ.km
Operating Voltage 300/500 V
Test Voltage 1000 V
Temperature Range -30°C   –   +90°C (fixed)
Min. Bending Radius 7,5 x  cable diameter
Flame tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1 
Smoke Density IEC 61034-2, EN 61034-2
Corressive Gas Tests IEC 60754-1, EN 50267-2
Circuit Integrity Tests                FE180 IEC 60331-21
Circuit Integrity Tests  PH120 EN 50200
         
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401200802 2x2x0,75 8,5 42 88
3401200803 3x2x0,75 10,4 59 120
3401200804 4x2x0,75 11,8 77 160
3401200805 5x2x0,75 12,6 94 195
3401200806 6x2x0,75 12,8 108 220
3401200808 8x2x0,75 14 140 270
3401200810 10x2x0,75 15,2 170 372
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401201002 2x2x1,00 9,2 53 115
3401201003 3x2x1,00 10,8 76 145
3401201004 4x2x1,00 12,5 100 195
3401201005 5x2x1,00 13,1 120 240
3401201006 6x2x1,00 13,4 142 270
3401201008 8x2x1,00 14,8 180 340
3401201010 10x2x1,00 16 225 415
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401201502 2x2x1,50 11,4 75 139
3401201503 3x2x1,50 12,8 106 185
3401201504 4x2x1,50 14,4 138 240
3401201505 5x2x1,50 15,6 168 295
3401201506 6x2x1,50 16,3 198 350
3401201508 8x2x1,50 17,6 256 441
3401201510 10x2x1,50 20 322 550
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3401202502 2x2x2,50 12,9 114 188
3401202503 3x2x2,50 14,5 164 270
3401202504 4x2x2,50 16,7 214 385
3401202505 5x2x2,50 18 260 415
3401202506 6x2x2,50 19,3 308 545
3401202508 8x2x2,50 20,6 410 640
3401202510 10x2x2,50 22,4 502 760

Address: Akcaburgaz Mah. 3109. Sok No:3/3 Esenyurt/Istanbul/TURKEY
Phone: +90 212 672 92 24 (pbx) - Fax: +90 212 672 92 26
E-mail: birikim@birikimkablo.com - Export: export@birikimkablo.com