JE-H(St)H…Bd FE180 PH120

 

JE-H(St)H…Bd FE180 PH120

Application

These cables are used in industrial electronics, control engineering applications, electronic devices and automation systems, fire alarm and supression systems especially in public buildings such as hotels, schools, hospitals, shopping centers etc. They have low smoke density and they don’t emit poisonous and corrosive gases during a fire therefore they don’t harm human health. They can function under flame for 180 minutes according to tests done as per IEC 60331-21 and maintain 120 minutes circuit integrity according to tests done as per EN50200 which simulate the fire and hazardous conditions.

Construction
Conductor IEC 60228, EN 60228, VDE 0295 CLASS-1 Solid copper wire
Insulation Cross-linked elastomer silicone insulation | BS EN 50363-1, HD 22.1 S4(EI2)
Colour Code VDE 0815                                            
Lay up The cores to quads and the guads are stranded to units
Separator Polyester tape
Flame Barrier Fiberglass tape
Screen Solid tinned copper wire, Aluminium foil 100% coverage
Outher sheath HFFR | EN 50290-2-27, VDE0207(HM2)
Outher Sheath Colour RAL 2004 Orange
Specifications
Loop Resistance
Wire diameter (mm) Ω/km (max.)
0,8 73,2
1,12 43,8
1,37 23
1,75 14,5
Insulation Resistance >100MΩ.km
Operating Voltage 300 V
Test Voltage 1000 V
Mutual Capacitance 120 nF/km
Temperature Range -30°C   –   +90°C (fixed)
Min. Bending Radius 7,5 x  cable diameter
Flame tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1 
Smoke Density IEC 61034-2, EN 61034-2
Corressive Gas Tests IEC 60754-1, EN 50267-2
Circuit Integrity Tests   FE180 IEC 60331-21
Circuit Integrity Tests  PH120 EN 50200
         
Product Code Number of  Cores ×Cross Section (mm)  Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3451000801 1x2x0,80 mm 5,8 11 38
3451000802 2x2x0,80 mm 6,8 21 57
3451000803 3x2x0,80 mm 8,1 30,5 78
3451000804 4x2x0,80 mm 8,9 41 97
3451000805 5x2x0,80 mm 9,7 47 105
3451000808 8x2x0,80 mm 11 79 162
3451000810 10x2x0,80 mm 13,1 100 210
Product Code Number of  Cores ×Cross Section (mm)  Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3451001001 1x2x1,00 mm 6 18,5 49
3451001002 2x2x1,00 mm 7,8 32,8 72
3451001003 3x2x1,00 mm 8,8 47 120
3451001004 4x2x1,00 mm 10,6 62 145
3451001005 5x2x1,00 mm 11,7 77 190
3451001008 8x2x1,00 mm 13,3 121 262
3451001010 10x2x1,00 mm 14,6 158 320
Product Code Number of  Cores ×Cross Section (mm²) Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3451001101 1x2x1,00 mm² 6,2 21 56
3451001102 2x2x1,00 mm² 8 39 88
3451001103 3x2x1,00 mm² 9,1 58 128
3451001104 4x2x1,00 mm² 11 76 168
3451001105 5x2x1,00 mm² 12 95 208
3451001108 8x2x1,00 mm² 14,1 150 307
3451001110 10x2x1,00 mm² 15 195 378
Product Code Number of  Cores ×Cross Section (mm²)  Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3451001501 1x2x1,50 mm² 8 33 65
3451001502 2x2x1,50 mm² 9,2 65 115
3451001503 3x2x1,50 mm² 10,9 88 175
3451001504 4x2x1,50 mm² 12,7 120 205
3451001505 5x2x1,50 mm² 13,8 143 295
3451001508 8x2x1,50 mm² 18 232 410
3451001510 10x2x1,50 mm² 20 283 490

Address: Akcaburgaz Mah. 3109. Sok No:3/3 Esenyurt/Istanbul/TURKEY
Phone: +90 212 672 92 24 (pbx) - Fax: +90 212 672 92 26
E-mail: birikim@birikimkablo.com - Export: export@birikimkablo.com