RE-Y(St)YSWBY-fl

 

RE-Y(St)YSWBY-fl

Application

Instrumentation cables are preferred in the industrial applications of petrochemical plants, power plants, steel & aluminium factories, water treatment plants, pipelines and industrial buildings of the oil and gas industry and similar projects where measurement and control of data is crucial and the project environment can be demanding. Birikim Kablo follows national/international standards or customers specific requests when designing these cables.

Construction
Reference Standard EN 50288-7
Conductor IEC 60228, CLASS-2 Stranded electrolytic annealed copper wire
Insulation PVC | EN 50290-2-21 (TI52), VDE0207(YI2)
Colour Code Pair : White-black cores  with numbers      
Triple : White-black-red cores  with numbers                                         
Lay up Two cores twisted in pair and pairs stranded together
Screen Polyester tape, Aluminium foil 100% coverage
Drain wire Stranded Tinned Copper
Inner sheath PVC | EN 50290-2-22 
Armour Galvanized steel wire braiding
Outer sheath Flame Retardant, UV Resistant PVC  | EN 50290-2-22
Outer sheath color RAL 5015 Blue / RAL 9005 Black
         
Specifications
Mutual Capacitance (800 MHz)  250(pF/m)
Capacitance Unbalance 500 pF/ 500 m
Insulation Resistance >100MΩ.km
Conductor Resistance
Cross Section  (mm2) Conductor resistance Ω/km (max.) L/R Ratio(µH/Ω)
0,5 36 25
0,75 24,5 25
1 18,1 25
1,3 14,2 40
1,5 12,1 40
2,5 7,41 60
Operating Voltage 300/500 V
Test Voltage 2000 V
Temperature Range -30°C   –   +70°C (fixed)
Min. Bending Radius 10 x  cable diameter
Oil Resistance ICEA S-82-552
Flame tests IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1
IEC 60332-3-24 , EN 60332-3-24 
Alternative designs:  Yw – Heat resistant PVC (105 °C)
PiMF, TiMF and QiMF screen types
C – Copper or tinned copper braided
Yv/Hv – Reinforced outer sheath
RE-2G - Fire resistant (silicon based)
RE-m2X - Fire resistant (mica tape based)
Communication core can be added upon request   
Product Code  Number of  Cores × Cross section (mm2) Cable Diameter (mm ±5%) Copper Weight  (kg/km) Cable Weight  (kg/km)
33112010504 2x2x0,50 11,2 29 195
33112010508 4x2x0,50 13 48 240
33112010516 8x2x0,50 16,1 85 360
33112010520 10x2x0,50 17,8 104 430
33112010524 12x2x0,50 18,8 125 485
33112010532 16x2x0,50 20,6 162 595
33112010540 20x2x0,50 21,7 202 690
33112010548 24x2x0,50 24,3 240 800
         
33112010804 2x2x0,75 12 40 220
33112010808 4x2x0,75 13,85 70 290
33112010816 8x2x0,75 17,4 125 450
33112010820 10x2x0,75 19,8 154 522
33112010824 12x2x0,75 20,6 181 600
33112010832 16x2x0,75 22,5 240 730
33112010840 20x2x0,75 23,7 300 875
33112010848 24x2x0,75 27,2 356 1040
         
33112011004 2x2x1,0 13,5 50 240
33112011008 4x2x1,0 15,2 90 335
33112011016 8x2x1,0 18,9 166 510
33112011020 10x2x1,0 21,5 205 620
33112011024 12x2x1,0 22,4 242 710
33112011032 16x2x1,0 24,4 320 895
33112011040 20x2x1,0 25,7 396 1060
33112011048 24x2x1,0 29,7 470 1210
         
33112011304 2x2x1,3 13,8 62 305
33112011308 4x2x1,3 15,9 115 408
33112011316 8x2x1,3 20 210 640
33112011320 10x2x1,3 22,9 265 790
33112011324 12x2x1,3 24,2 312 880
33112011332 16x2x1,3 26,9 415 990
33112011340 20x2x1,3 27,9 514 1260
33112011348 24x2x1,3 32,4 620 1495
         
33112011504 2x2x1,5 14,9 72 325
33112011508 4x2x1,5 16,95 130 430
33112011516 8x2x1,5 21,3 244 700
33112011520 10x2x1,5 24 300 860
33112011524 12x2x1,5 25,4 360 980
33112011532 16x2x1,5 28,3 472 1190
33112011540 20x2x1,5 30 585 1410
33112011548 24x2x1,5 34,4 710 1720

Address: Akcaburgaz Mah. 3109. Sok No:3/3 Esenyurt/Istanbul/TURKEY
Phone: +90 212 672 92 24 (pbx) - Fax: +90 212 672 92 26
E-mail: birikim@birikimkablo.com - Export: export@birikimkablo.com