Application | ||||
They are used as connection cables in outdoor and underground at CATV, cable TV, satellite systems. |
||||
Construction | ||||
Conductor | 1,02 mm Electrolytic annealed copper | |||
Insulation | 4,60 mm Physical foamed polyethylene | |||
Foil Screen | Copper foil 100% coverage | |||
Screen | Copper wire braiding | |||
Outher sheath | 6,90 mm PE | EN 50290-2-24 | |||
Outher Sheath Colour | RAL 9005 Black | |||
Specifications | ||||
Impedance | 75 Ω | |||
Mutual Capacitance | 54 pF/m | |||
Conductor Resistance | 22 Ω/km(max.) | |||
Insulation Resistance | >2000MΩ.km | |||
Operating Voltage | 1,3 kV (max.) | |||
Test Voltage | 3 kV | |||
Temperature Range | -30°C – +70°C (fixed) | |||
Min. Bending Radius | 10 x cable diameter | |||
Cable Weight | 45 (kg/km) | |||
Smoke Density | IEC 61034-2, EN 61034-2 | |||
Corressive Gas | IEC 60754-1 ,EN 50267-2 | |||
Attenuations | ||||
Frequency (MHz) | (dB/100m) | |||
230 | 10,5 | |||
470 | 14,5 | |||
860 | 20 | |||
1000 | 22 | |||
1500 | 27,8 | |||
2000 | 33 | |||
2400 | 37 | |||
3000 | 42 | |||
Return Loss | ||||
Frequency (MHz) | (dB/100m) | |||
5-470 | 23 | |||
470-862 | 20 | |||
862-1000 | 18 | |||
Standard Packing | ||||
Standard Packing | 100 m Roll / PVC Spool | |||
300 m Plywood Spool | ||||
500 m Plywood Spool | ||||
1000 m Plywood Spool |