Application | |||||
These cables are used in electronic control devices, servo motors, valves, public announcement systems and automation applications where cable flexibility and signal quality is vital. Shielded and braided types provide better protection against electromagnetic interference. |
|||||
|
|||||
Reference Standard | VDE 0812 | ||||
Conductor | IEC 60228, EN 60228, VDE 0295 CLASS-5 Stranded electrolytic annealed copper wire | ||||
Insulation | PVC | EN 50290-2-21 (TI52), VDE0207(YI2) | ||||
Colour Code | DIN 47100 | ||||
Lay up | Cores stranded in layers | ||||
Separator | Polyester tape | ||||
Screen | Tinned copper wire braiding | ||||
Inner sheath | PVC | EN 50290-2-22 (TM52), VDE0207(YM2) | ||||
Separator | Polyester tape | ||||
Screen | Tinned copper wire braiding | ||||
Outher sheath | PVC | EN 50290-2-22 (TM52), VDE0207(YM2) | ||||
Outher Sheath Colour | RAL 7001 Grey | ||||
Specifications | |||||
Conductor Resistance | |||||
Cross Section (mm2) | Ω/km (max.) | ||||
0,14 | 148 | ||||
0,22 | 96 | ||||
0,25 | 79,9 | ||||
0,34 | 53 | ||||
0,5 | 38,9 | ||||
0,75 | 26 | ||||
1 | 19,5 | ||||
1,5 | 13,3 | ||||
2,5 | 7,98 | ||||
Operating Voltage | |||||
Cross Section (mm2) | Voltage | ||||
0,14 – 0,34 | 250 V | ||||
0,50 – 2,50 | 300/500 V | ||||
Test Voltage | |||||
Cross Section (mm2) | Voltage | ||||
0,14 - 0,22 | 800 V | ||||
0,22 – 1,00 | 1200 V | ||||
1,50 – 2,50 | 2500 V | ||||
Insulation Resistance | >200MΩ.km | ||||
Temperature Range | -30°C – +70°C (fixed) | ||||
Min. Bending Radius | 7,5 x cable diameter | ||||
Flame tests | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-2-1 | ||||